The collector system grounding for wind power plants (WPPs) is the primary concern of this guide. This guide is not intended for the WPP substation; however, since the substation is typically interconnected with the collector system, its design might affect or be affected by the collector system. With proper consideration, the methods described herein could be used in determining the impact of the collector system on substation safety and vice versa. Quantitative analysis of the effects of lightning surges is beyond the scope of this document. Similarly, this guide does not cover offshore wind power plants, battery energy storage facilities, solar power plants, or substation grounding
- Standard Committee
- PE/EDPG - Energy Development & Power Generation
- Status
- Active Standard
- PAR Approval
- 2016-09-22
- Board Approval
- 2020-09-24
- History
-
- Published:
- 2021-01-29
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/EDPG - Energy Development & Power Generation
- Working Group
-
WSPPCD - Wind and Solar Plant Collector Design Working Group
Learn More About WSPPCD - Wind and Solar Plant Collector Design Working Group - IEEE Program Manager
- Vanessa Lalitte
Contact Vanessa Lalitte - Working Group Chair
- Loren Powers
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
2778-2020
IEEE Guide for Solar Power Plant Grounding for Personnel Protection
This guide is primarily concerned with the grounding system design for photovoltaic solar power plants that are utility owned and/or utility scale (5 MW or greater). The focus of the guide is on differences in practices from substation grounding as provided in IEEE Std 80. This guide is not intended for the substations to interconnect the plant; however, if the substation is included within the plant, portions of this guide may be applicable. Similarly, this guide does not directly cover small scale solar power plants (such as rooftop type systems), substation grounding, or lightning protection.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards