As the unique pathway of traction power reflux, the multi-point mobile grounding system plays a critical role in providing safer power supply for electrified railway. The multi-point mobile grounding system of electrified railway contains two types of grounding modes–working grounding and protective grounding. However, along with the traction power increasing, it is possible that the traction current discharged by the working grounding flows through the neighboring protective grounding points back to the vehicle bodies; then this vehicle body (VB) current may flee through other protective grounding points back to the rail again during the dynamic process of the vehicles, forming as the current reflux phenomenon. This VB current reflux may directly result in thermal surge in the partial part of train bodies, or cause the contact potential of vehicle bodies, which may interfere or even burn the low-voltage control systems or on-board sensors. Apart from threatening the on-board equipment, the uneven distribution of reflux locating at each wheel set of carriage may also result in the erosion of the isolated joint of rail or even shorten the life span of carbon brush contacting with the axles of grounding wheels. This guide applies to the design and requirement of grounding system for vehicles operation in electrified railway.
- Standard Committee
- VT/TPSSC - Traction Power Systems Standards Committee
- Status
- Active Standard
- PAR Approval
- 2018-03-08
- Board Approval
- 2023-06-05
Working Group Details
- Society
- IEEE Vehicular Technology Society
- Standard Committee
- VT/TPSSC - Traction Power Systems Standards Committee
- Working Group
-
multi-point grounding system o - Guide for multi-point grounding system of trains in electrified railway
Learn More About multi-point grounding system o - Guide for multi-point grounding system of trains in electrified railway - IEEE Program Manager
- Meng Zhao
Contact Meng Zhao - Working Group Chair
- Guoqiang Gao
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards