Characteristics of ventilated dry-type transformers relating to performance, limited electrical and mechanical interchangeability, as well as recommended practice for installation of equipment are set forth in this guide. Specific rating combinations are described up to 7500 kVA high-voltage class from 1.2 kV to 36 kV inclusive, and low voltage class up to 5 kV. This guide also describes certain electrical and mechanical requirements and takes into consideration certain desirable features of 60 Hz, two-winding, three-phase, ventilated dry-type transformers. Clause 9 through Clause 11 describe other requirements or alternatives that may be specified for some applications.
- Standard Committee
- PE/TR - Transformers
- Status
- Active Standard
- PAR Approval
- 2017-05-18
- Superseding
- C57.12.51-2008
- Board Approval
- 2019-05-21
- History
-
- Published:
- 2019-09-06
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/TR - Transformers
- Working Group
-
DryType-WGC57.12.51 - Dry Type - Ventilated Dry-type Working Group
Learn More About DryType-WGC57.12.51 - Dry Type - Ventilated Dry-type Working Group - IEEE Program Manager
- Patrycja Jarosz
Contact Patrycja Jarosz - Working Group Chair
- Sanjib Som
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C57.12.51-2008
IEEE Standard for Ventilated Dry- Type Power Transformers, 501 kVA and Larger, Three-Phase, with High- Voltage 601 V to 34 500 V; Low- Voltage 208Y/120 V to 4160 V- General Requirements
This standard is intended to set forth characteristics relating to performance, limited electrical and mechanical interchangeability, and safety of the equipment described, and to assist in the proper selection of such equipment. Specific rating combinations are described in the range from 750/1000 to 7500/10 000 kVA inclusive, with high-voltage 601 to 34 500 volts inclusive and low-voltage 208Y/120 to 4160 volts inclusive. Part I of this standard describes certain electrical and mechanical requirements and takes into consideration certain safety features of 60-Hz, two-winding, three-phase, ventilated dry-type transformers with self-cooled ratings 501 kVA and larger, generally used for step-down purposes. Part Il describes other requirements or alternatives which may be specified for some applications and lists forced-air-cooled ratings for certain sizes.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards