Superseded Standard

IEEE 1017-2004

IEEE Recommended Practice for Field Testing Electric Submersible Pump Cable

Procedures and test voltage values for acceptance and maintenance testing of electrical submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.

Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Status
Superseded Standard
PAR Approval
1998-09-16
Superseded by
1017-2013
Superseding
1017-1991
Board Approval
2004-09-23
History
ANSI Approved:
2005-03-10
Published:
2005-04-13

Working Group Details

Society
IEEE Industry Applications Society
Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Working Group
ESP WG - ESP Working Group
Learn More About ESP WG - ESP Working Group
IEEE Program Manager
Patricia Roder
Contact Patricia Roder
Working Group Chair
Robert Durham

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P1017.4
IEEE Draft Recommended Practice for Testing and Rating of Electrical Submersible Pump Motors

This standard specifies procedures and test values for testing and rating of Electrical Submersible Pump (ESP) motors as well as installation and handling practices. The specified procedures and test values apply to ESP motor systems rated 3 kV through 8 kV (phase to phase).

Learn More About P1017.4

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1017.1-2021
IEEE Recommended Practice for Testing of Electric Submersible Pump Cable

Procedures and test voltage values for factory, acceptance, and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV through 8 kV (phase to phase) and is intended only for this special purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.

Learn More About 1017.1-2021

1017.2-2021
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation

Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethyleneu2013propylene rubber insulation, nitrile jacket, ethyleneu2013propylene diene monomer (EPDM) jacket or metallic barrier, and armor or encapsulating material. These cables are for voltages not exceeding 8 kV (phase to phase) and conductor temperatures not exceeding 140 u00baC (284 u00baF) for nitrile or a maximum of 232 u00baC (450 u00baF) for EPDM jacket or metallic barrier cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.

Learn More About 1017.2-2021

1017.3-2021
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Polypropylene Insulation

Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene insulation, nitrile or polypropylene jacket, or metallic barrier or armor. These cables are for voltages not exceeding 8 kV (phase to phase) and conductor temperatures not exceeding 96 u00b0C (205 u00b0F) maximum or u201310 u00b0C (14 u00b0F) minimum. Conductors, insulation, barrier(optional), assembly with or without jacket, and armor or encapsulating material, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.

Learn More About 1017.3-2021

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1017-2013
IEEE Recommended Practice for Field Testing Electric Submersible Pump Cable

Procedures and test voltage values for acceptance and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.

Learn More About 1017-2013

1018-2004
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Ethylene-Propylene Rubber Insulation

Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with ethyleneu2013 propylene rubber insulation, nitrile jacket, ethyleneu2013propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 u00baC (284 u00baF) for nitrile or a maximum of 204 u00baC (400 u00baF) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.

Learn More About 1018-2004

1018-2013
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation

Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethyleneu2013propylene rubber insulation, nitrile jacket, ethyleneu2013propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 u00baC (284 u00baF) for nitrile or a maximum of 232 u00baC (450 u00baF) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.

Learn More About 1018-2013

1019-2004
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Polypropylene Insulation

Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 u00baC (205 u00baF) for nitrile or a maximum of u201310 u00baC (14 u00baF). Conductors, insulation, assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.

Learn More About 1019-2004

1019-2013
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable–Polypropylene Insulation

Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile or polyethylene jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 u00baC (205 u00baF) maximum for nitrile or a maximum minimum of u201310 u00baC (14 u00baF) minimum. Conductors, insulation, assembly and with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.

Learn More About 1019-2013

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.