The application of protective relays on transmission-line series capacitor banks is covered. The purpose of this guide is to provide the reader with ample discussion of the protection and control issues related to series capacitor bank installations. Specific examples related to protective functions and testing procedures are provided.
- Standard Committee
- PE/PSRCC - Power System Relaying and Control
- Status
- Superseded Standard
- PAR Approval
- 1999-12-07
- Superseded by
- C37.116-2018
- Board Approval
- 2007-02-07
- History
-
- ANSI Approved:
- 2007-09-25
- Published:
- 2007-08-07
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/PSRCC - Power System Relaying and Control
- Working Group
-
ADMIN_8200 - Project Administration_8200
Learn More About ADMIN_8200 - Project Administration_8200
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
C37.117-2007
IEEE Guide for the Application of Protective Relays Used for Abnormal Frequency Load Shedding and Restoration
Information on the application of under frequency load shedding and restoration to ac power systems is compiled in this guide. Various system conditions that may require the use of under frequency load shedding, and the application of protective relays to various methods of performing under frequency load shedding are described in this guide. Some practical examples of under frequency load shedding applications are also provided
C37.234-2009
IEEE Guide for Protective Relay Applications to Power System Buses
Concepts of power bus protection are discussed in this guide. Consideration is given to availability and location of breakers, current transformers, and disconnectors as well as bus-switching scenarios, and their impact on the selection and application of bus protection. A number of bus protection schemes are presented; their adequacy, complexity, strengths, and limitations with respect to a variety of bus arrangements are discussed; specific application guidelines are provided. Breaker failure protection is discussed as pertaining to bus protection. Means of securing bus protection schemes against corrupted relay input signals are also included.