Superseded Standard

IEEE C37.230-2007

IEEE Guide for Protective Relay Applications to Distribution Lines

A review of generally accepted applications and coordination of protection for radial power system distribution lines is presented. The Guide examines the advantages and disadvantages of schemes presently being used in protecting distribution lines. Identification of problems with the methods used in distribution line protection and the solutions for those problems are included.

Standard Committee
PE/PSRCC - Power System Relaying and Control
Status
Superseded Standard
PAR Approval
2003-06-12
Superseded by
C37.230-2020
Board Approval
2007-09-27
History
ANSI Approved:
2008-03-25
Published:
2008-02-08

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/PSRCC - Power System Relaying and Control
Working Group
C37.230_WG-D28 - Protective Relay Applications to Distribution Lines Working Group
Learn More About C37.230_WG-D28 - Protective Relay Applications to Distribution Lines Working Group
IEEE Program Manager
Malia Zaman
Contact Malia Zaman
Working Group Chair
Brian Boysen

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.230-2020
IEEE Guide for Protective Relay Applications to Distribution Lines

A review of generally accepted applications and coordination of protection for power system distribution lines is presented. The advantages and disadvantages of schemes presently being used in protecting distribution lines are examined in this guide. Identification of problems with the methods used in distribution line protection and the solutions for those problems is included.

Learn More About C37.230-2020

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.