PC37.90.1

Standard for Relays, Relay Systems, and Control Devices used for Protection and Control of Electric Power Apparatus-Surge Withstand Capability (SWC) and Electrical Fast Transient (EFT) Requirements and Tests

This standard specifies design tests for relays, relay systems, and control devices used for Protection and Control of Electric Power Apparatus, that relate to the immunity of this equipment to repetitive electrical transients. Two types of tests are specified, the oscillatory (SWC) and electrical fast transient (EFT) tests. For devices with communication ports, where the device does not perform protection or control functions, testing of the communication functions is covered by IEEE Standard 1613. Where the device performs protection or control functions and has communication ports, tests for all communication functions are covered by this document. For devices without communication ports, the tests are covered by this document.

Standard Committee
PE/PSRCC - Power System Relaying and Control
Joint Sponsors
EMC/SDCom
Status
Active PAR
PAR Approval
2020-09-24
Superseding
C37.90.1-2012

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/PSRCC - Power System Relaying and Control
Working Group
C37.90.1_WG/I40 - WG for PC37.90.1 Standard for Relays, Relay Systems, and Control Devices used for Protection and Control of Electric Power Apparatus-Surge Withstand Capability (SWC) and Electrical Fast Transient (EFT) Requirements and Tests
Learn More About C37.90.1_WG/I40 - WG for PC37.90.1 Standard for Relays, Relay Systems, and Control Devices used for Protection and Control of Electric Power Apparatus-Surge Withstand Capability (SWC) and Electrical Fast Transient (EFT) Requirements and Tests
IEEE Program Manager
Malia Zaman
Contact Malia Zaman
Working Group Chair
Roger Whittaker

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


C37.90.1-2012
IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus

Two types of design tests for relays and relay systems that relate to the immunity of this equipment to repetitive electrical transients are specified. Test generator characteristics, test waveforms, selection of equipment terminals on which tests are to be conducted, test procedures, criteria for acceptance and documentation of test results are described. This standard has been harmonized with IEC standards where consensus could be reached.

Learn More About C37.90.1-2012