Recommendations believed essential for the application of overcurrent protective devices applied to limit the exposure time of transformers to short circuit current are set forth. Transformer coordination curves are presented for four categories of transformers. There is no intent to imply overload capability.
- Standard Committee
- PE/TR - Transformers
- Status
- Superseded Standard
- Superseded by
- C57.109-1993
- Board Approval
- 1983-06-23
- History
-
- ANSI Approved:
- 1985-08-19
- Published:
- 1985-12-02
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/TR - Transformers
- Working Group
-
PerfCharac-WGC57.109 - Performance Characteristics - Liquid-Immersed Transformers Working Group
Learn More About PerfCharac-WGC57.109 - Performance Characteristics - Liquid-Immersed Transformers Working Group - IEEE Program Manager
- Malia Zaman
Contact Malia Zaman - Working Group Chair
- Vinay Mehrotra
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
C57.109-2018
IEEE Guide for Liquid-Immersed Transformers Through-Fault-Current Duration
Recommendations believed essential for the application of overcurrent protective devices applied to limit the exposure time of transformers to short circuit current are set forth. Transformer coordination curves are presented for four categories of transformers. There is no intent to imply overload capability.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C57.109-1993
IEEE Guide for Liquid-Immersed Transformers Through-Fault-Current Duration
Recommendations believed essential for the application of over current protective devices applied to limit the exposure time of transformers to short-circuit current are set forth. Transformer coordination curves are presented for four categories of transformers. There is no intent to imply overload capability