Conformance test requirements are provided for current and inductively-coupled voltage transformers used for measurement and control functions in unit substations at primary system voltages above 600 V, but not exceeding 38 kV, except for those in certain installations as set forth in the standard. The selection of transformers for conformance testing, the basis for conformance, and the treatment of failures within a test sequence are covered. Impulse, voltage-withstand, accuracy, and temperature rise are specified. Insulation systems acceptance and production monitoring are considered
- Standard Committee
- PE/TR - Transformers
- Status
- Inactive-Withdrawn Standard
- Superseded by
- C57.13.2-2005
- Superseding
- C57.13.2-1986
- Board Approval
- 1991-12-05
- History
-
- Withdrawn:
- 1997-12-09
- ANSI Approved:
- 1992-12-23
- Published:
- 1992-07-10
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/TR - Transformers
- Working Group
-
Instrument-WGC57.13 - Instrument Transformers - Req for Inst. Xfrmrs
Learn More About Instrument-WGC57.13 - Instrument Transformers - Req for Inst. Xfrmrs - IEEE Program Manager
- Malia Zaman
Contact Malia Zaman - Working Group Chair
- David Wallace
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
PC57.13
Standard Requirements for Instrument Transformers
To assist in the proper selection of Instrument Transformers this standard defines requirements for performance and interchangeability. Safety precautions are also addressed. This standard defines certain electrical, dimensional, and mechanical characteristics, and takes into consideration certain safety features of current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control. This standard defines the requirements for Class 1 instrument transformers. For instrument transformers of a nominal system voltage of 115 kV and above if Class 2 is required refer to IEEE Std C57.13.5(TM).
PC57.13-2016/Cor 1
Standard Requirements for Instrument Transformers - Corrigendum 1
This standard is intended for use as a basis for performance and interchangeability of equipment covered, and to assist in the proper selection of such equipment. Safety precautions are also addressed. This standard covers certain electrical, dimensional, and mechanical characteristics, and takes into consideration certain safety features of current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
C57.13-2016
IEEE Standard Requirements for Instrument Transformers
Electrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control of equipment associated with the generation, transmission, and distribution of alternating current. The aim is to provide a basis for performance and interchangeability of equipment covered and to assist in the proper selection of such equipment. Safety precautions are also addressed. Accuracy classes for metering service are provided. The test code covers measurement and calculation of ratio and phase angle, demagnetization, impedance and excitation measurements, polarity determination, resistance measurements, short-time characteristics, temperature rise tests, dielectric tests, and measurement of open-circuit voltage of current transformers.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C57.13-1978
IEEE Standard Requirements for Instrument Transformers
Superseded. Electrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control of equipment associated with the generation, transmission, and distribution of alternating current. The aim is to provide a basis for performance, interchangeability, and safety of equipment covered and to assist in the proper selection of such equipment. Accuracy classes for metering service are provided. The test code covers measurment and calculation of radio and phase angle, demagnetization, impedance and excitation measurements, polarity determination, resistance measurements, short-time characteristics, temperature rise tests, dielectric tests, and measurment of open-circuit voltage of current transformers.
C57.13-1993
IEEE Standard Requirements for Instrument Transformers
Superseded by IEEE Std C57.13-2008. Electrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control of equipment associated with the generation, transmission, and distribution of alternating current. The aim is to provide a basis for performance, interchangeability, and safety of equipment covered, and to assist in the proper selection of such equipment. Accuracy classes for metering service are provided. The test code covers measurement and calculation of ratio and phase angle, demagnetization, impedance and excitation measurements, polarity determination, resistance measurements, short-time characteristics, temperature-rise tests, dielectric tests, and measurement of open-circuit voltage of current transformers. Interpretations are available at http://standards-qa21.ieee.org/reading/ieee/interp/C57.13-1993.html
C57.13-2008
IEEE Standard Requirements for Instrument Transformers
Electrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control of equipment associated with the generation, transmission, and distribution of alternating current. The aim is to provide a basis for performance and interchangeability of equipment covered and to assist in the proper selection of such equipment. Safety precautions are also addressed. Accuracy classes for metering service are provided. The test code covers measurement and calculation of ratio and phase angle, demagnetization, impedance and excitation measurements, polarity determination, resistance measurements, short-time characteristics, temperature rise tests, dielectric tests, and measurement of open-circuit voltage of current transformers.
C57.13.2-1986
American National Standard Conformance Test Procedures for Instrument Transformers
The purpose of this standard is to cover conformance test requirements for current and inductively coupled voltage transformers used for measurement and control functions in unit substations at primary system voltages above 600 V, but not exceeding 38 kV. The report describes relevant performance tests to demonstrate compliance with the applicable standards. The test specimen is normally subjected to all planned routine tests prior to the initiation of the conformance test program.