Active PAR

PC57.139

Guide for the Interpretation of Gases generated in Liquid-Type Load Tap Changers

This guide describes methods of evaluating dissolved gases in insulating liquids used with load tap changers (LTCs). General types of LTC mechanisms, breathing configurations, and electrical design are included for evaluation criteria in determining when mechanical damage, deterioration or failure might have occurred.

Standard Committee
PE/TR - Transformers
Status
Active PAR
PAR Approval
2022-03-24
Superseding
C57.139-2015

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/TR - Transformers
Working Group
InsFluid-WG57.139 - Insulating Fluids - DGA in LTCs Working Group
Learn More About InsFluid-WG57.139 - Insulating Fluids - DGA in LTCs Working Group
IEEE Program Manager
Patrycja Jarosz
Contact Patrycja Jarosz
Working Group Chair
Rainer Frotscher

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C57.139-2015
IEEE Guide for Dissolved Gas Analysis in Transformer Load Tap Changers

General types of load tap changer (LTC) mechanisms, breathing configurations, and electrical designs, described for reference for determining methods of testing and evaluating dissolved gases in mineral-based transformer oils in LTCs, are discussed and recommended in this guide. Measurements of dissolved gas concentrations in the LTC oil are required to implement this guide. This guide is not manufacturer specific, rather category specific. ** Downloads file posted at http://standards-qa21.ieee.org/downloads/C57/C57.139-2015/

Learn More About C57.139-2015

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C57.139-2010
IEEE Guide for Dissolved Gas Analysis in Transformer Load Tap Changers

Methods of testing and evaluating dissolved gases in mineral based transformer oils found in Load Tap Changers (LTCs) are discussed and recommended in this guide. General types of LTC mechanisms, breathing configurations and electrical design are included as evaluation criteria for determining when mechanical damage or failure has occurred. Dissolved Gas of the LTC is required. This guide is not manufacturer specific, rather category specific. Additional files for download can be found at http://standards-qa21.ieee.org/downloads/C57/C57.139-2010/

Learn More About C57.139-2010

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards