The effects of geomagnetic disturbances (GMD) on power transformers when there is the presence of geomagnetically induced current (GIC) in a power transformer are described. Specification parameters and performance characteristics for power transformers to help minimize the risk and impact when GIC is present in the power system are established. The intent is to provide a background that can help evaluate the effect of GIC on a power transformer design and its GIC capability. This includes the evaluation techniques to determine the performance characteristics while under the influence of GIC.
- Standard Committee
- PE/TR - Transformers
- Status
- Active Standard
- PAR Approval
- 2014-03-27
- Corrigendum
-
C57.163-2015/Cor 1-2016
- Board Approval
- 2015-09-03
- History
-
- Published:
- 2015-10-26
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/TR - Transformers
- Working Group
-
Stds-WGC57.163 - Standards - Transformer Capability Under Geomagnetic Disturbance WG
Learn More About Stds-WGC57.163 - Standards - Transformer Capability Under Geomagnetic Disturbance WG - IEEE Program Manager
- Malia Zaman
Contact Malia Zaman - Working Group Chair
- Daniel Blaydon
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
PC57.163
IEEE Draft Guide for Establishing Power Transformer Capability while under Geomagnetic Disturbances
The effects of geomagnetic disturbances (GMD) on power transformers when there is the presence of geomagnetically induced current (GIC) in a power transformer are described. Specification parameters and performance characteristics for power transformers to help minimize the risk and impact when GIC is present in the power system are established. The intent is to provide a background that can help evaluate the effect of GIC on a power transformer design and its GIC capability. This includes the evaluation techniques to determine the performance characteristics while under the influence of GIC.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
C57.163-2015/Cor 1-2016
IEEE Guide for Establishing Power Transformer Capability while under Geomagnetic Disturbances - Corrigendum 1
Clarified in this corrigendum to IEEE Std C57.163™-2015 is the derivation of the tie plate temperatures shown in Figure 13.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards