Inactive-Reserved Standard

IEEE C62.82.1-2010

IEEE Standard for Insulation Coordination--Definitions, Principles, and Rules

Revision of IEEE Std 1313.1-1996. The procedure for selection of the withstand voltages for equipment phase-to-ground and phase-to-phase insulation systems is specified. A list of standard insulation levels, based on the voltage stress to which the equipment is being exposed, is also identified. This standard applies to three-phase ac systems above 15 kV.

Standard Committee
PE/SPDC - Surge Protective Devices Committee
Status
Inactive-Reserved Standard
PAR Approval
2010-06-17
Superseding
1313.1-1996
Board Approval
2010-12-08
History
Published:
2011-04-15
Inactivated Date:
2021-03-25

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SPDC - Surge Protective Devices Committee
Working Group
HV3.4.18 - 3.4.18 Preferred Voltages & Insulation Coordination Std Maintenance WG
Learn More About HV3.4.18 - 3.4.18 Preferred Voltages & Insulation Coordination Std Maintenance WG
IEEE Program Manager
Christian Orlando
Contact Christian Orlando
Working Group Chair
Jonathan Woodworth

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C62.82.2-2022
IEEE Guide for the Application of Insulation Coordination

The calculation method for selection of phase-to-ground and phase-to-phase insulation withstand voltages for equipment is presented. Methods for insulation coordination of different air-insulated systems like transmission lines and substations are outlined. The methods of analysis are illustrated by practical examples.

Learn More About C62.82.2-2022

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1313.1-1996
IEEE Standard for Insulation Coordination - Definitions, Principles and Rules

The procedure for selection of the withstand voltages for equipment phase-to-ground and phase-to-phase insulation systems is specified. A list of standard insulation levels, based on the voltage stress to which the equipment is being exposed, is also identified. This standard applies to three-phase ac systems above 1 kV.

Learn More About 1313.1-1996

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


1312-1993
IEEE Standard Preferred Voltage Ratings for Alternating-Current Electrical Systems and Equipment Operating at Voltages Above 230 kV Nominal

Perferred voltage ratings above 230 kV nominal for alternating-current (ac) systems and equipment are provided, along with definitions of various types of system voltages.

Learn More About 1312-1993

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


1313.2-1999
IEEE Guide for the Application of Insulation Coordination

The calculation method for selection of phase-to-ground and phase-to-phase insulation withstand voltages for equipment is presented. This guide gives methods for insulation coordination of different air-insulated systems like transmission lines and substations. The methods of analysis are illustrated by practical examples.

Learn More About 1313.2-1999