Revision of IEEE Std 1313.1-1996. The procedure for selection of the withstand voltages for equipment phase-to-ground and phase-to-phase insulation systems is specified. A list of standard insulation levels, based on the voltage stress to which the equipment is being exposed, is also identified. This standard applies to three-phase ac systems above 15 kV.
- Standard Committee
- PE/SPDC - Surge Protective Devices Committee
- Status
- Inactive-Reserved Standard
- PAR Approval
- 2010-06-17
- Superseding
- 1313.1-1996
- Board Approval
- 2010-12-08
- History
-
- Published:
- 2011-04-15
- Inactivated Date:
- 2021-03-25
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/SPDC - Surge Protective Devices Committee
- Working Group
-
HV3.4.18 - 3.4.18 Preferred Voltages & Insulation Coordination Std Maintenance WG
Learn More About HV3.4.18 - 3.4.18 Preferred Voltages & Insulation Coordination Std Maintenance WG - IEEE Program Manager
- Christian Orlando
Contact Christian Orlando - Working Group Chair
- Jonathan Woodworth
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
C62.82.2-2022
IEEE Guide for the Application of Insulation Coordination
The calculation method for selection of phase-to-ground and phase-to-phase insulation withstand voltages for equipment is presented. Methods for insulation coordination of different air-insulated systems like transmission lines and substations are outlined. The methods of analysis are illustrated by practical examples.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
1313.1-1996
IEEE Standard for Insulation Coordination - Definitions, Principles and Rules
The procedure for selection of the withstand voltages for equipment phase-to-ground and phase-to-phase insulation systems is specified. A list of standard insulation levels, based on the voltage stress to which the equipment is being exposed, is also identified. This standard applies to three-phase ac systems above 1 kV.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
1312-1993
IEEE Standard Preferred Voltage Ratings for Alternating-Current Electrical Systems and Equipment Operating at Voltages Above 230 kV Nominal
Perferred voltage ratings above 230 kV nominal for alternating-current (ac) systems and equipment are provided, along with definitions of various types of system voltages.
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
1313.2-1999
IEEE Guide for the Application of Insulation Coordination
The calculation method for selection of phase-to-ground and phase-to-phase insulation withstand voltages for equipment is presented. This guide gives methods for insulation coordination of different air-insulated systems like transmission lines and substations. The methods of analysis are illustrated by practical examples.