Active PAR

P1283

Guide for Determining the Effects of Elevated Temperature Operation on Conductors, Connectors, and Accessories

This guide describes the effects and impacts of elevated temperature operation on conductors, connectors, and accessories. The guide identifies operating metrics which constitute elevated temperature operation based on present industry practices and its effects on overhead line components, and suggest potential mitigation options to manage and/or avoid identified adverse impacts.

Standard Committee
PE/T&D - Transmission and Distribution
Status
Active PAR
PAR Approval
2020-09-24
Superseding
1283-2013

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/T&D - Transmission and Distribution
Working Group
TPC-Conductor - Conductor Working Group P1283
Learn More About TPC-Conductor - Conductor Working Group P1283
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
John Mcdaniel

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1283-2013
IEEE Guide for Determining the Effects of High-Temperature Operation on Conductors, Connectors, and Accessories

Possible adverse impacts to an operating overhead transmission line which might occur when operating the line at high temperatures are discussed. Specifically, the transmission line's conductor, connectors, and attached accessories in terms of degradation in mechanical properties due to annealing elastic and in-elastic elongation, and accelerated aging are explored along with limited mitigation recommendations. Additionally, predictor equations for accelerated creep and conductor loss of strength are detailed in annexes with limited example calculations.

Learn More About 1283-2013

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.