This recommended practice includes information on the design, installation, and configuration of battery management systems in stationary applications, including both grid-interactive, standalone cycling and standby modes. This document covers battery management hardware, software, and configuration. Hardware capabilities in large systems include: grounding and isolation; passive and active balancing; and wired or wireless sensors. Software capabilities include: algorithms for optimal operation with reduced risk; best practices for verification and validation; alarms; and communication with external systems. Common settings are discussed along with setting selection methods. Battery types that this document covers include lithium-ion, sodium-beta, advanced lead-acid, and flow batteries. General factors for other types are provided. This document does not cover battery management systems for mobile applications such as electric vehicles; nor does it include operation in vehicle-to-grid applications. Energy management systems, which control the dispatch of power and energy to and from the grid, are not covered.
- Standard Committee
- PE/ESSB - Energy Storage & Stationary Battery Committee
- Status
- Active PAR
- PAR Approval
- 2018-09-27
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/ESSB - Energy Storage & Stationary Battery Committee
- Working Group
-
WG_2686 - Battery Management Systems in Energy Storage Applications
Learn More About WG_2686 - Battery Management Systems in Energy Storage Applications - IEEE Program Manager
- Michael Kipness
Contact Michael Kipness - Working Group Chair
- David Rosewater
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards