The use of some electrical equipment attached to typical power systems creates power quality concerns. There is an increasing awareness that some equipment is not designed to withstand the surges, faults, distortion, and reclosing duty present on typical utility distribution systems. Traditional concerns about steady-state voltage levels and light flicker due to voltage fluctuation also remain. These concerns are addressed by this guide by documenting typical levels of these aspects of power quality and indicating how to improve them. Other documents that treat these subjects in more detail are referenced.
- Standard Committee
- PE/T&D - Transmission and Distribution
- Status
- Active Standard
- PAR Approval
- 2017-03-23
- Superseding
- 1250-2011
- Board Approval
- 2018-09-27
- History
-
- Published:
- 2018-11-16
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/T&D - Transmission and Distribution
- Working Group
-
PQ-1250_WG - P1250_Voltage Quality Working Group
Learn More About PQ-1250_WG - P1250_Voltage Quality Working Group - IEEE Program Manager
- Michael Kipness
Contact Michael Kipness - Working Group Chair
- Nicholas Zagrodnik
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
1564-2014
IEEE Guide for Voltage Sag Indices
Appropriate voltage sag indices and characteristics of electrical power and supply systems as well as the methods for calculating them are identified. Methods are provided for quantifying the severity of individual voltage sag events, for quantifying the performance at a specific location (single-site indices), and for quantifying the performance of the whole system (system indices). Multiple methods are presented for each. The methods are appropriate for use in transmission, distribution, and utilization electric power systems.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
1250-2011
IEEE Guide for Identifying and Improving Voltage Quality in Power Systems
The use of some electrical equipment attached to typical power systems creates voltage quality concerns. There is an increasing awareness that some equipment is not designed to withstand the surges, faults, distortion, and reclosing duty present on typical utility distribution systems. Traditional concerns about steady-state voltage levels and light flicker due to voltage fluctuation also remain. These concerns are addressed by this guide by documenting typical levels of these aspects of voltage quality and indicating how to improve them. Other documents that treat these subjects in more detail are referenced.