Inactive-Reserved Standard

IEEE 303-2004

IEEE Recommended Practice for Auxiliary Devices for Rotating Electrical Machines in Class I, Division 2 and Zone 2 Locations

Revision of IEEE Std 303-1991 This recommended practice applies to the application and installation procedures of auxiliary devices in or on electric rotating machines that are employed in hazardous locations classified as Class I, Division 2 or Class I Zone 2 under commonly used worldwide regulations. These regulations are: the National Electrical Code (United States); the Canadian Electrical Code, Part 1 (Canada); and combined practices of the International Electrotechnical Commission (IEC), the European Committee for Electrotechnical Standardization (CENELEC), and Standards Australia / Standards New Zealand (AS/NZS). Included is a list of source documents, definitions and nomenclature. Devices include terminal housings, heaters, surge protection, power factor correction capacitors, shaft grounding, and enclosures. Special marking requirements are also discussed.

Sponsor Committee
IAS/PCI - Petroleum and Chemical Industry
Learn More About IAS/PCI - Petroleum and Chemical Industry
Status
Inactive-Reserved Standard
PAR Approval
2002-12-11
Superseding
303-1991
Board Approval
2004-06-24
History
ANSI Approved:
2004-12-16
Published:
2004-12-17
Reaffirmed:
2011-12-07
Inactivated Date:
2022-03-24

Working Group Details

Society
IEEE Industry Applications Society
Learn More About IEEE Industry Applications Society
Sponsor Committee
IAS/PCI - Petroleum and Chemical Industry
Learn More About IAS/PCI - Petroleum and Chemical Industry
Working Group
303_WG - Division 2 & Zone 2 Aux. Devices
Learn More About 303_WG - Division 2 & Zone 2 Aux. Devices
IEEE Program Manager
Patricia Roder
Contact Patricia Roder
Working Group Chair
Arthur Neubauer

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P303

IEEE Draft Recommended Practice for Auxiliary Devices for Rotating Electrical Machines in Class I, Division 2 and Zone 2 Locations and Class II, Division 2 and Zone 22 Locations

This recommended practice is limited to auxiliary devices associated with rotating electrical machines operating in Class I Division 2 and Zone 2 or Class II Division 2 and Zone 22 areas, as classified under the practice of the National Fire Protections Association (NFPA) standard NFPA 70, National Electrical Code(R) (NEC(R)) and the Canadian Standards Association (CSA) standard CSA C22.1, Canadian Electrical Code (CE Code). This recommended practice is not an attempt to rewrite or otherwise supersede applicable sections or clauses of these noted documents or any other codes or ordinances. Rather, it is intended to serve as a supplement to existing codes that in this area may not be sufficiently specific to serve as a guide to good engineering practice.

Learn More About P303

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.