This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control cables using insulation resistance measurements in the detail necessary to produce accurate and reproducible results during simulated accident conditions. It includes the requirements for the measurement system and measurement procedure, and the reporting of the measurement results. NOTE Measurement of insulation resistance during simulated accident conditions with the aim of determining the lowest value during the accident in order to assess cable performance involves special requirements given in this document. Methods for measurement under stable (non-accident) conditions are available in other international standards, e.g. IEC 62631-3-3. The different parts of the IEC/IEEE 62582 series are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEC/IEEE 60780-323.
- Standard Committee
- PE/NPE - Nuclear Power Engineering
- Status
- Active Standard
- PAR Approval
- 2015-12-05
- Board Approval
- 2019-09-05
- History
-
- Published:
- 2019-10-21
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/NPE - Nuclear Power Engineering
- Working Group
-
WG_2.1 - Working Group on Equipment Qualification
Learn More About WG_2.1 - Working Group on Equipment Qualification - IEEE Program Manager
- Christian Orlando
Contact Christian Orlando - Working Group Chair
- John White
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P62582-1
Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 1: General
This part of IEC/IEEE 62582 contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods. IEC/IEEE 62582 specifies condition monitoring methods in sufficient detail to enhance the accuracy and repeatability, and provide standard formats for reporting the results. The methods specified are applicable to electrical equipment containing organic or polymeric materials. Some methods are specially designed for the measurement of the condition of a limited range of equipment whilst others can be applied to all types of equipment for which the organic parts are accessible. Although the scope of IEC/IEEE 62582 is limited to the application of instrumentation and control systems important to safety, the condition monitoring methods may be applicable also to other components which include organic or polymeric materials. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. For the technical background of condition monitoring methods, reference is made to other IEC standards, e.g. IEC 60544-5. Information on the role of condition monitoring in the qualification of equipment important to safety is found in IEC/IEEE Std 60780-323. General information on management of ageing can be found in IEC 62342 and IEEE 1205. NOTE The procedures defined in IEC/IEEE 62582 are intended for detailed condition monitoring. A simplified version of the procedures may be appropriate for preliminary assessment of the need for detailed measurements.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
60780-323-2016
IEC/IEEE International Standard - Nuclear facilities -- Electrical equipment important to safety -- Qualification
This International Standard describes the basic requirements for qualifying electrical equipment important to safety and interfaces (electrical and mechanical) that are to be used in nuclear facilities. The principles, methods, and procedures described are intended to be used for qualifying equipment, maintaining and extending qualification, and updating qualification, as required, if the equipment is modified. The qualification requirements in this standard, when met, demonstrate and document the ability of equipment to perform safety function(s) under applicable service conditions, including design basis events and certain design extension conditions, and reduce the risk of environmentally induced common-cause equipment failure. This standard does not provide environmental stress levels or performance requirements. Other aspects, relating to quality assurance, selection and use of electronic devices, design and modification of digital systems are not part of this standard. Other IEC or IEEE standards that present qualification programmes for specific equipment, specific environments, or specific parts of the qualification programme may be used to supplement this standard, as applicable. The bibliography lists other standards related to equipment qualification.
62582-5-2015
IEEE/IEC International Standard - Nuclear power plants -- Instrumentation and control important to safety -- Electrical equipment condition monitoring methods -- Part 5: Optical time domain reflectometry
This part of IEC/IEEE 62582 contains methods for monitoring the attenuation condition of optical fibres and cables in instrumentation and control systems using optical time domain reflectometer (OTDR) measurements in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for the measurement system and conditions, and the reporting of the measurement results. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of IEC/IEEE 62582 and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEEE Std 323. Detailed descriptions of methods for OTDR measurement of the quality and functionality of fibre optic cables are given in IEC 61280-4-1 for multimode attenuation and in IEC 61280-4-2 for single-mode attenuation.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
62582-1-2011
Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 1: General
IEC/IEEE 62582-1:2011 contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods.
62582-2-2011
IEC/IEEE International Standard - Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 2: Indenter modulus
IEC/IEEE 62582-2:2011 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using the indenter modulus technique in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for the selection of samples, the measurement system and measurement conditions, and the reporting of the measurement results. (English and French version)
62582-2-am1-2015
IEC/IEEE International Standard for Nuclear power plants -- Instrumentation and control important to safety -- Electrical equipment condition monitoring methods -- Part 2: Indenter modulus - Amendment 1
The scope is the correction of Figure 1, Figure 2, Figure A. 1 and Figure B.1 of IEC/IEEE 62582-2:2011.
62582-3-2012
IEC/IEEE International Standard - Nuclear Power Plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 3: Elongation at break
This standard contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using tensile elongation techniques in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for selection of samples, the measurement system and conditions, and the reporting of the measurement results. Standards in the IEC/IEEE 62582-series are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582-1 General includes requirements for the application of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEEE Std 323. This standard is intended for application to non-energised equipment.
62582-4-2011
Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 4: Oxidation induction techniques
IEC/IEEE 62582-4:2011 specifies methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using oxidation induction techniques in the detail necessary to produce accurate and reproducible measurements. It includes the requirements for sample preparation, the measurement system and conditions, and the reporting of the measurement results.