IEEE C57.154-2012

IEEE Standard for the Design, Testing, and Application of Liquid-Immersed Distribution, Power, and Regulating Transformers Using High-Temperature Insulation Systems and Operating at Elevated Temperatures

All liquid-immersed distribution, power, and regulating transformers that are designed to operate at temperatures that exceed the normal thermal limits of IEEE C57.12.00TM under continuous load, in the designed average ambient, and at rated conditions are covered by this standard. Specific requirements and guidance in the design, testing, and application of the transformers covered within the scope of this standard are provided. High-temperature insulation systems or systems that use a combination of high-temperature and conventional insulation are incorporated by these transformers.

Standard Committee
PE/TR - Transformers
Status
Superseded Standard
PAR Approval
2011-11-09
Superseded by
C57.154-2022
Board Approval
2012-08-30
History
Published:
2012-10-30

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/TR - Transformers
Working Group
InsLife-WGC57.154 - Insulation Life - Standard for the design, testing and application of liquid-immersed distribution, power and regulating transformers using high-temperature insulation systems
Learn More About InsLife-WGC57.154 - Insulation Life - Standard for the design, testing and application of liquid-immersed distribution, power and regulating transformers using high-temperature insulation systems
IEEE Program Manager
Malia Zaman
Contact Malia Zaman
Working Group Chair
Richard Marek

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C57.154-2022
IEEE Standard for Liquid-Immersed Transformers Designed to Operate at Temperatures Above Conventional Limits Using High- Temperature Insulation Systems

Covered in this standard are all liquid-immersed distribution, power, and regulating transformers that are designed to operate at temperatures that exceed the normal thermal limits of IEEE C57.12.00 under continuous load, in the designed average ambient, and at rated conditions. Specific requirements and guidance in the design, testing, and application of the transformers covered within the scope of this standard are provided. High-temperature insulation systems or systems that use a combination of high-temperature and conventional insulation are incorporated by these transformers.

Learn More About C57.154-2022

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.