Standard for Design Tests and Specifications for High-Voltage (> 1000 V) Fuses and Accessories

This standard establishes design tests and specifications for high-voltage (above 1000 V) fuses and accessories for use on alternating current (ac) electrical distribution systems. Devices with rated maximum voltages to 170 kV are covered. The devices to which this standard applies are as follows: a) Expulsion fuses (including fuse cutouts); b) Current-limiting fuses; c) Items a) and b) used in fuse-enclosure packages; d) Fuse supports of the type intended for use with fuses and fuse disconnecting switches; e) Disconnecting devices (fuse disconnecting switches, disconnecting switches, and disconnecting cutouts) created by the use of a removable fuse unit or switch blade in a fuse support; f) Expulsion, current-limiting, and combination types of external capacitor fuses used with a capacitor unit, a group of units, or capacitor banks; g) Backup current-limiting fuses ("motor-starter fuses") used in conjunction with high-voltage motor starters; h) Fuse links when used exclusively with expulsion fuses and fuse disconnecting switches; i) Items a) through f) having integral load-break means; j) accessories including mounting brackets and switch sticks (switch hooks). This standard may also be used as a basis for testing other devices that are similar to the devices listed in the scope. In addition, the parts relating to expulsion fuses may, where applicable, be used for non-expulsion fuses in which the interruption process waits for a natural current zero to clear the circuit.

Standard Committee
PE/SWG - Switchgear
Status
Active PAR
PAR Approval
2020-03-05
Superseding
C37.41-2016

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SWG - Switchgear
Working Group
HVF-WG_C37.41 - HVF - IEEE Standard for Design Tests and Specifications for High-Voltage (> 1000 V) Fuses and Accessories
Learn More About HVF-WG_C37.41 - HVF - IEEE Standard for Design Tests and Specifications for High-Voltage (> 1000 V) Fuses and Accessories
Working Group Chair
Sterlin Cochran

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.41-2016
IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses and Accessories

Revision of IEEE C37.41-2008 and supersedes IEEE C37.40-2003. Required procedures for performing design tests for high-voltage fuses, as well as for fuse disconnecting switches, are specified. These design tests, as appropriate to a particular device, include the following test types: dielectric, interrupting, radio-influence, temperature-rise, time-current, manual-operation, liquid-tightness, thermal-cycle, bolt-torque, withstand tests for motor circuit fuses, expulsion fuses using polymeric insulators, load-break, and short-time current.

Learn More About C37.41-2016

C37.41-2016/Cor 1-2017
IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses and Accessories Corrigenda 1

Corrigenda concerning required procedures for performing design tests for high-voltage fuses are specified. These design tests, are appropriate to expulsion fuses, and cover interrupting tests and fuses using polymeric insulators.

Learn More About C37.41-2016/Cor 1-2017

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C37.41-2000
IEEE Standard Design Tests For High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories

Required procedures for performing design tests for high-voltage distribution-class and power-class fuses, as well as for fuse disconnecting switches and enclosed single-pole air switches are specified. These design tests, as appropriate to a particular device, include the following test types-dielectric, interrupting, load-break, making current, radio-influence, short-time current, temperature-rise, time-current, mechanical, and liquid-tightness.

Learn More About C37.41-2000

C37.41-2008
IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices

Required procedures for performing design tests for high-voltage distribution class and power class fuses, as well as for fuse-disconnecting switches and enclosed single-pole air switches, are specified. These design tests, as appropriate to a particular device, include the following test types: dielectric, interrupting, load-break, radio-influence, short-time current, temperature rise, time-current, manual operation, thermal-cycle, bolt torque, and liquid tightness.

Learn More About C37.41-2008

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.